View Issue Details

IDProjectCategoryView StatusLast Update
0003442ardourbugspublic2020-04-19 20:14
Reporternolaiz Assigned Tocth103  
PrioritynormalSeveritymajorReproducibilityalways
Status closedResolutionfixed 
Target Version3.0-beta1 
Summary0003442: Ardour hangs when trying to connect any master-bus input when it have more than 2 channels
DescriptionAfter adding more channels to the master-bus, Ardour hangs when trying to connect a track output to any master-bus input.
TagsNo tags attached.

Activities

cth103

2010-09-06 21:06

administrator   ~0008998

A couple of related bugs are now fixed in SVN; could you check whether this is fixed?

nolaiz

2010-09-07 07:55

reporter   ~0008999

Yes, it is. Thanks a lot! :)

cth103

2010-09-07 10:13

administrator   ~0009002

Cool, thanks for the report.

system

2020-04-19 20:14

developer   ~0022218

Issue has been closed automatically, by Trigger Close Plugin.
Feel free to re-open with additional information if you think the issue is not resolved.

Issue History

Date Modified Username Field Change
2010-09-06 09:34 nolaiz New Issue
2010-09-06 10:36 cth103 cost => 0.00
2010-09-06 10:36 cth103 Target Version => 3.0-beta1
2010-09-06 21:06 cth103 Note Added: 0008998
2010-09-06 21:06 cth103 Status new => feedback
2010-09-07 07:55 nolaiz Note Added: 0008999
2010-09-07 10:13 cth103 Note Added: 0009002
2010-09-07 10:13 cth103 Status feedback => resolved
2010-09-07 10:13 cth103 Resolution open => fixed
2010-09-07 10:13 cth103 Assigned To => cth103
2020-04-19 20:14 system Note Added: 0022218
2020-04-19 20:14 system Status resolved => closed