Summary | 0008989: Clocks showed "<<<<" at 96k sample rate | ||||
Description | At 96k sample rate: Clocks showed "<<<<"; Tempo and Time Signature is empty | ||||
Steps To Reproduce | Create new session with sample rate 96000 | ||||
Tags | No tags attached. | ||||
related to | 0009024 | new | Ardour 7 - Windows 10 crash after calling context menu in Ardour time display |
|
|
|
Confirmed. You can work-around this by editing the `ui_config` file (while ardour is not running) using a text-editor: On Linux: $HOME/.config/ardour7/ui_config On Windows: %localappdata%\ardour7\ui_config On Mac: ~/Library/Preferences/Ardour7/ui_config and change "clock-display-limit" to 0 (zero): <Option name="clock-display-limit" value="0"/> |
|
Fixed in 7.0-17-g8240875379 |
Date Modified | Username | Field | Change |
---|---|---|---|
2022-10-15 15:29 | unius | New Issue | |
2022-10-15 15:29 | unius | File Added: shot.png | |
2022-10-16 14:09 | x42 | Status | new => confirmed |
2022-10-16 14:09 | x42 | Note Added: 0026610 | |
2022-10-16 14:09 | x42 | Note Edited: 0026610 | |
2022-10-16 20:00 | x42 | Assigned To | => x42 |
2022-10-16 20:00 | x42 | Status | confirmed => resolved |
2022-10-16 20:00 | x42 | Resolution | open => fixed |
2022-10-16 20:00 | x42 | Note Added: 0026611 | |
2022-10-17 15:41 | unius | Status | resolved => closed |
2022-10-21 18:49 | x42 | Relationship added | related to 0009024 |