Summary0005170: add an ebu r128 meter to the master bus
DescriptionA3 should add Fons' ebur128 as optional meter info for the master bus.
volume should be integrated between start/stop cycles.

details and code:
http://kokkinizita.linuxaudio.org/linuxaudio/ebumeter-doc/quickguide.html
TagsNo tags attached.

Activities

x42

2020-04-27 02:30

administrator   ~0023955

EBU-R128 is available post-export (stereo only), Ardour's master-bus may have any number of channels so only EBU bar-graph meters are supported (since 3.5)