Summary | 0002612: LV2 ':scalePoint' labels not interpreted properly | ||||
Description | LV2 allows for labels to be defined to help explain what values on sliders mean. When this is utilised Ardour changes the control to a dropdown that only allows the label values to be selected. ie a pan control can be defined as: a lv2:InputPort, lv2:ControlPort ; lv2:index 3 ; lv2:symbol "pan" ; lv2:name "Pan" ; lv2:default 0.0 ; lv2:minimum -1.0 ; lv2:maximum 1.0 ; Ardour interprets this as a slider with a range of -1 -> 1 When scale points are added to allow Ardour to mark where Left and Right is (after all the slider is vertical) a lv2:InputPort, lv2:ControlPort ; lv2:index 3 ; lv2:symbol "pan" ; lv2:name "Pan" ; lv2:default 0.0 ; lv2:minimum -1.0 ; lv2:maximum 1.0 ; lv2:scalePoint [ rdfs:label "Left" ; rdf:value -1.0 ; ] , [ rdfs:label "Center" ; rdf:value 0.0 ; ] , [ rdfs:label "Right" ; rdf:value 1.0 ; ] Ardour now interprets this control as a dropdown with three values. | ||||
Additional Information | $uname -a Linux arch-lv2 2.6.28-ARCH 0000001 SMP PREEMPT Tue Mar 17 07:22:53 CET 2009 x86_64 AMD Athlon(tm) 64 X2 Dual Core Processor 4800+ AuthenticAMD GNU/Linux ardour version: 2.8 slv2: version 0.6.2 | ||||
Tags | No tags attached. | ||||
|
What plugin are you seeing this problem with? |
|
I cannot vouch for the original poster, but I am encountering this issue with my so-404 synthesizer. One of my control ports determines the Midi Channel which it listens on, i.e. the port is defined in the ttl as [ a lv2:InputPort; a lv2:ControlPort; lv2:index 9; lv2:symbol "channel"; lv2:name "Midi Channel"; lv2:portProperty lv2:integer; lv2:default 0; lv2:minimum 0; lv2:maximum 16; lv2:scalePoint [ rdfs:label "Off"; rdf:value 16 ]; ] Preferably, Ardour would present some sort of integer selection widget, and display the text "Off" somehow when the value 16 is selected. At the least, Ardour should ignore lv2:scalePoints *except* when the port is explicitly specified as an "enumeration", in which case creating a drop-down menu of just the scalePoints is the right thing to do. Otherwise, I would say it is more important to allow the user to input all possible values than it is to display their labels. Note: I am testing this on Ardour 3 Beta 9. |
|
This should be a bit better in SVN 11745. Still needs some work to mark up sliders with scalePoint labels. |
Date Modified | Username | Field | Change |
---|---|---|---|
2009-04-03 07:10 | obleak | New Issue | |
2010-04-24 10:28 | cth103 | Category | bugs => bugs2 |
2010-04-24 10:31 | cth103 | Category | bugs2 => bugs |
2010-05-02 11:49 | cth103 | Note Added: 0007745 | |
2010-05-02 11:49 | cth103 | Status | new => feedback |
2011-08-05 02:54 | jeremybub | Note Added: 0011260 | |
2011-08-05 02:55 | jeremybub | Note Edited: 0011260 | |
2011-08-05 02:55 | jeremybub | Note Edited: 0011260 | |
2011-08-12 15:59 | cth103 | cost | => 0.00 |
2011-08-12 15:59 | cth103 | Target Version | => 3.0-beta1 |
2011-11-15 15:57 | cth103 | Target Version | 3.0-beta1 => 3.0-beta2 |
2011-12-27 13:13 | cth103 | Status | feedback => confirmed |
2012-01-10 20:45 | cth103 | Target Version | 3.0-beta2 => 3.0-beta3 |
2012-02-14 17:20 | paul | Target Version | 3.0-beta3 => 3.0 beta4 |
2012-03-21 17:38 | cth103 | Note Added: 0013002 | |
2012-05-23 15:08 | cth103 | Target Version | 3.0 beta4 => 3.0 |