View Issue Details

IDProjectCategoryView StatusLast Update
0001425ardourfeaturespublic2008-11-20 23:50
Reporterallan_k Assigned Topaul  
PrioritynormalSeveritytweakReproducibilityalways
Status closedResolutionfixed 
Summary0001425: control and seq ports as 2 separate ports under one midi client or rename seq client to something other than ardour.
DescriptionSimple startup scripts to connect MIDI devices don't function correctly in ardour2
due to their being 2 alsa MIDI devices both called ardour.

This problem can be alleviated either by appearing under the same device (but as different ports)
i.e. when issuing acconect -o they it would look like

client 128: 'ardour' [type=user]
    0 'control
    1 'seq

or
client 128: 'ardour' [type=user]
    0 'control '
client 129: 'ardseq' [type=user]
    0 'seq

cheers

Allan



TagsNo tags attached.

Activities

paul

2007-01-15 18:59

administrator   ~0003068

fixed in svn, rev 1329

Issue History

Date Modified Username Field Change
2007-01-14 05:14 allan_k New Issue
2007-01-15 18:59 paul Status new => resolved
2007-01-15 18:59 paul Resolution open => fixed
2007-01-15 18:59 paul Assigned To => paul
2007-01-15 18:59 paul Note Added: 0003068
2008-11-20 23:50 seablade Status resolved => closed